Alarm Zone Types
Jun 04, 2018


Alarm Zone Types


Zone Types Definition of HY-518 PSTN/GSM Alarm System



1 Disable

   This zone does not adopt the type.


2  Delay Zone

   It is mainly used for access route (eg: front door: entrance). Arming will be enabled when delay is over, so please disarm

the system before delay is finished, or it will give an alarm. The siren will give the prompt tone when alarm is delaying (As a

prompt signal for disarming).


3  Burglar Zone 

    It is mainly used for the inner door or inner window. It will give an urgent alarm when burglary happens. No delay.


4 Perimeter Zone 

    It is mainly used for the external door or external window. It will give an urgent alarm when burglary happens. No delay.


5 Day-night Zone(zone alerts when disarming, zone alarms when arming)

    It is mainly used for door or window with door sensor (eg: shop) or the “sensitive” sites, such as commodity library, medicine warehouse and so on, or some sites need to pay great attention. Under the disarming status, if zone’s detector is triggered, panel will beep “ding dong”; under the arming status, if zone’s detector is triggered, panel will give an alarm. 


6 Silent Alarm

   It is mainly used for the SOS button (eg: bank, jewelry counter). When pressing the button, it will send alarm report to the Contact ID, but not give any sounds. And the zone No. will be shown in the front panel. 


7 Audible Alarm

   It is mainly used for the SOS button. It not only can send the alarm report to Contact ID, but also give a vocal alarm (eg: emergency alarm in bed). And zone No. will be shown in the front panel. Besides, the zone will not be influenced by arming/disarming.


8 Fire Zone

   It is used for some sites with smoke detectors or heat detectors. When the detectors are triggered, it will send the fire signal to panel and the zone number will be shown in the front panel. Meanwhile, the panel will drive the siren to give a vocal alarm and send the report to Contact ID. Besides, the zone will not be influenced by arming/disarming.


9 Gas Zone 

   It is used for some sites with gas detector or other gas detectors. When detectors are triggered, it will send the signal to panel and the zone number will be shown in the front panel. Meanwhile, the panel will drive the siren to give a vocal alarm and send the report to Contact ID. Besides, zone will not be influenced by arming/disarming.


10 Medical Zone 

   It is used for some sites with SOS button or other emergency help equipments. When detectors are triggered, it will send the signal to panel and the zone number will be shown in the front panel. Meanwhile, the panel will drive the siren to give a vocal alarm and send the report to Contact ID. Besides, zone will not be influenced by arming/disarming.


11 Doorbell Zone

   It is similar with Day-night zone type. No matter under arming or disarming status, when detectors are triggered, panel will beep “ding dong”, but not output alarm voice. 


12 Key Switch Zone 

    It is only used for wired zones with arming/disarming lock. When fault zone turns into normal zone, panel will auto-arm;

when normal zone turns into fault zone, panel will auto-disarm. 


13 One Button Intercom

   It’s use for some sites with SOS button or other emgency help equipment. When detectors are triggered, the alarm panel will dial preset alarm numbers, when users answer the calling, then go into two way intercom. Users can set the preset alarm number at directive address [125], and the alarm phone type must set as GSM dialing, ordinary voice.